Readings that cross a line, devices that go quiet.
Keep a running total for every sensor, machine and gateway, rolled up to its site and region. Aggrelis tells your systems when readings stay over a limit, and when a device stops reporting at all.
watching
watching
watching
The questions this answers
Typical questions, each with the window it usually looks at. Thresholds are starting points you set yourself.
- Over a limit, for a while
How many readings above 8 °C did this container have, and what was the highest?
rolling 30 minutes - Gone silent
Which devices have sent no heartbeat for 10 minutes?
no event for 10 minutes - Errors per site
Which site, and which region, has the most device errors this hour?
rolling 1 hour, device → site → region - Failing firmware
How many different devices on this firmware version reported errors?
rolling 24 hours, distinct devices - Energy per local day
How many kilowatt-hours did this meter use today, against its daily cap?
calendar day, building's time zone - Off its own norm
Is this machine's vibration far outside its own last seven days?
rolling 7 days, standard deviation
Open a ticket when a gateway goes quiet
A gateway in a cold store stops sending heartbeats. Ten minutes later Aggrelis pushes a signed webhook to your on-call tool, with the last heartbeat and the errors across the gateway's site, so on-call can tell one dead device from a site in trouble. Nothing has to poll.
- Send a heartbeat from each gateway, and each error it reports
- Define heartbeats per gateway, errors rolled up to the site, and a trigger that fires after 10 minutes of silence
- Be told: the trigger pushes the answer as a signed webhook
- Act: open a ticket for one silent gateway, page on-call when its site is failing too
{
"id": "hb_gw17_1029",
"type": "heartbeat",
"ts": "2026-10-22T10:12:41Z",
"attrs": {
"gateway_id": "gw_17",
"firmware": "fw-4.2.1"
}
}{
"name": "gateway_health",
"description": "Is this gateway alive, and its site healthy?",
"spec": {
"entity": "gateway",
"features": {
"heartbeats15m": {"state": "heartbeats_by_gateway",
"window": {"rolling": "15m"}},
"lastHeartbeatAt": {"state": "heartbeats_by_gateway",
"window": "lifetime", "select": "last"},
"siteErrors1h": {"state": "errors_by_gateway",
"path": "gateway_at", "window": {"rolling": "1h"}}
},
"reasons": [
{"name": "gone_silent",
"when": "now - lastHeartbeatAt > duration('10m')"},
{"name": "site_degraded", "when": "siteErrors1h >= 10"}
],
"triggers": [
{"name": "silent", "on": "heartbeat", "absent": "10m"}
]
}
}{
"type": "trigger.result",
"timestamp": "2026-10-22T10:22:44.208113402Z",
"data": {
"trigger": "silent",
"profile": "gateway_health",
"timing": "absence",
"status": "ok",
"entity": {"type": "gateway", "id": "gw_17"},
"values": {
"heartbeats15m": 5,
"lastHeartbeatAt": "2026-10-22T10:12:41Z",
"siteErrors1h": 14
},
"reasons": ["gone_silent", "site_degraded"],
"event": {"id": "hb_gw17_1029", "type": "heartbeat",
"ts": "2026-10-22T10:12:41Z"},
"profileVersion": "gateway_health@v1"
}
}The parts of Aggrelis behind it
Nothing built for one industry: the same building blocks, configured for this job.
- Filters and maximums
Count only the readings over a limit, and keep the highest one per window.
- Device → site → region
One error counts for the device, its site and its region at once.
- Absence triggers
Fire when a device sends nothing for a time you choose, from one minute to 30 days.
- Signed webhooks
Results reach your on-call or ticketing tool, signed to the Standard Webhooks spec, or a stream you read.
- Local days, exact units
Energy per calendar day in each building's time zone, kept as exact decimals.
- Change without a release
Operations adjust limits in the workspace and test them on recent readings first.
Your first live numbers, configured not coded